A cable tray is one of the harder penetrations to firestop: lots of cables, a large opening, and — the real catch — it keeps changing as circuits are added and removed. The trick is a system that seals fully but can be opened and resealed without demolition.

The re-enterable problem

IT, security and electrical trades pull new cables through a tray for the life of a building. If you firestop it with a solid plug of sealant, every cable change means cutting it out and rebuilding the system — and inspectors know it usually doesn't happen. So for trays, the goal is a re-enterable system.

Firestop pillows: the standard for trays

Firestop pillows are the go-to: UL Classified bags that stack in and around the tray and between cable bundles to seal the opening — then pull out and re-stack whenever cables change. No caulk to cut, no system to rebuild. See firestop pillows & large-opening systems.

Sealant and cable coating

For smaller trays or the annular space around a sleeve, an intumescent firestop sealant may be listed. And to stop a fire from running along the cables themselves, C70 cable coating forms an intumescent jacket over grouped cables — standard in industrial plants, utilities and data centers. See C70 cable coating & accessories.

Frequently asked questions

What is the best way to firestop a cable tray?
Through a rated wall, firestop pillows are the standard — UL Classified, stacked around and between the cables, and fully re-enterable when circuits are added or removed. For permanent floor penetrations, mortar or composite-sheet systems apply. We match the UL system to your tray size and cable fill.
Pillows or sealant for a cable tray?
Pillows are preferred for trays because they are re-enterable — you can pull and re-stack them as cables change. Sealant is used for smaller trays or annular spaces where a listed system allows it, but it is not re-enterable once cured.
What does cable tray fire coating do?
C70 cable coating forms an intumescent, fire-retardant jacket over grouped cables so a cable fire cannot propagate along the tray. It is spray- or brush-applied and water-based — separate from firestopping the wall penetration itself, and often used together with it.