Firestop sealant (fire caulk) is the workhorse of passive fire protection: it seals through-penetrations and construction joints in fire-rated walls and floors so flame and smoke cannot pass. Every sealant here is a UL Classified Metacaulk® product from RectorSeal, tested to ASTM E814 (UL 1479) for penetrations and ASTM E1966 (UL 2079) for joints, with ratings up to 4 hours.

Which one you need depends on the assembly. Intumescent sealants (MC 150+, Metacaulk 1000, 350i) expand when heated and are the default for penetrations — cables, conduit, metallic and plastic pipe. Elastomeric MC 1200 flexes with moving joints and comes in caulk-grade, self-leveling and spray versions. Silicone 835+ handles weather exposure and Class 25 movement for curtain-wall and exterior joints. RS136 is the budget pick for basic penetrations, and SAS adds smoke and sound sealing where an STC rating matters.

Firestop-USA is an authorized Metacaulk master distributor: distributor pricing by the case or pallet, volume discounts, same-day shipping on in-stock items ordered before 11 AM, and free freight over $2,500 — with free UL system matching and submittal support.

Which one do I need?

General penetrations (cables, pipe, conduit)
MC 150+ — covers the most UL systems of any single sealant
High-movement or head-of-wall joints
MC 1200 elastomeric (caulk, self-leveling or spray)
Exterior / curtain wall / weather exposure
835+ silicone — Class 25 movement, ASTM C920
Sound ratings (walls between units)
SAS Smoke & Acoustic — seals smoke and sound
Budget jobs, basic penetrations
RS136 — economical, still UL Classified

Firestop Sealants — the lineup

Firestop Sealants — frequently asked

What is the difference between firestop sealant and regular caulk?

Regular caulk burns or melts in a fire. Firestop sealant is tested in specific UL Classified systems to maintain the fire rating of the wall or floor — intumescent types expand up to 18× when heated to close gaps around burning penetrants. Building codes require tested firestop systems, not generic caulk, in rated assemblies.

Which firestop sealant should I use for plastic (PVC/CPVC) pipe?

Plastic pipe needs an intumescent product that expands to crush the melting pipe — MC 150+ or Metacaulk 1000 in the appropriate UL system, often combined with a wrap strip or collar on larger diameters. Call (732) 757-4552 and we will match the exact UL system for your pipe size and assembly.

Are Metacaulk sealants UL Classified?

Yes — Metacaulk firestop sealants are UL Classified and tested to ASTM E814 (UL 1479) and ASTM E1966 (UL 2079) with ratings up to 4 hours, covering hundreds of UL systems. We provide the specific UL system documentation for your submittal at no charge.

How much firestop sealant do I need?

Coverage depends on the annular space and depth of the system. As a rule of thumb, a 10.1 oz tube fills about 18 cubic inches; a 20.2 oz sausage about 36. Send us your penetration schedule and we will take off the quantities for you — and pallet pricing kicks in fast on production jobs.

Need the right UL system?

Send your penetration schedule or a photo — we match the UL Classified system, provide submittal documentation free, and ship same-day from New Jersey at distributor pricing.